Samsung 2-way ceiling air conditioner 36.000Btu...

42,336,000 VND

TECHNICAL SPECIFICATIONS

Origin

:

Brand: Korea - Country of manufacture: China

Machine type

:

Non-inverter (no energy saving) - 2-way type

Cooling capacity

:

4.0 Hp (4.0 Horse) - 35.000 Btu/h

Use for room

:

Area 50 - 54 m² or 150 - 162 m³ gas (suitable for living room, office)

Power supply (Ph / V / Hz)

:1 phase, 220 - 240V, 50Hz

Power consumption of electricity

:3.25 Kw

Gas copper pipe size (mm)

:9.52 / 15.88

COOLER

Size of indoor unit (mm)

:

288 x 840 x 840 (mm)

Weight of indoor unit (Kg)

:

19 (kg)

OUTDOOR

Size of outdoor unit (mm)

:

967 x 880 x 320 (mm)

Weight of outdoor unit (Kg)

:

77 (kg)

Samsung 2-way Ceiling Cassette 48.000Btu AC140JN4DEH...

49,082,000 VND

TECHNICAL SPECIFICATIONS

Origin

:

Brand: Korea - Country of manufacture: China

Refrigerant type

:

R22

Machine type

:

Non-inverter (no energy saving) - 2-way type

Cooling capacity

:

5.0 Hp (5.0 Horse) - 48.000 Btu/h

Use for room

:

Area 64 - 67 m² or 192 - 201 m³ gas (suitable for living room, office)

Power supply (Ph / V / Hz)

:

1 phase, 220 - 240V, 50Hz

Power consumption of electricity

:

4.9 Kw

Gas copper pipe size (mm)

:

9.52 / 19.05

COOLER

Size of indoor unit (mm)

:

288 x 840 x 840 (mm)

Weight of indoor unit (Kg)

:

19 (kg)

OUTDOOR

Size of outdoor unit (mm

:

1.162 x 932 x 375 (mm)

Weight of outdoor unit (Kg)

:

90 (kg)

Samsung 1-way Ceiling Cassette 48.000Btu AC048HB4DED...

35,500,000 VND

TECHNICAL SPECIFICATIONS

Origin

:

Brand: Korea - Country of manufacture: China

Refrigerant type

:

R22

Machine type

:

Non-inverter (no power saving) - 1 way type (cooling only)

Cooling capacity

:

5.0 Hp (5.0 Horse) - 48.000 Btu/h

Use for room

:

Area 64 - 67 m² or 192 - 201 m³ gas (suitable for living room, office)

Power supply (Ph / V / Hz)

:

1 phase, 220 - 240V, 50Hz

Power consumption of electricity

:

4.9 Kw

Gas copper pipe size (mm)

:

9.52 / 19.05

COOLER

Size of indoor unit (mm)

:288 x 840 x 840 (mm)

Weight of indoor unit (Kg)

:19 (kg)

OUTDOOR

Size of outdoor unit (mm)

:1.162 x 932 x 375 (mm)

Weight of outdoor unit (Kg)

:90 (kg)

Samsung 1-way ceiling air conditioner 36.000Btu...

33,500,000 VND

TECHNICAL SPECIFICATIONS

Origin

:

Brand: Korea - Country of manufacture: China

Machine type

:

Non-inverter (no power saving) - 1 way type (cooling only)

Cooling capacity

:

4.0 Hp (4.0 Horse) - 35.000 Btu/h

Use for room

:

Area 50 - 54 m² or 150 - 162 m³ gas (suitable for living room, office)

Power supply (Ph / V / Hz)

:

1 phase, 220 - 240V, 50Hz

Power consumption of electricity

:

3.25 Kw

Gas copper pipe size (mm)

:

9.52 / 15.88

COOLER

Size of indoor unit (mm)

:

288 x 840 x 840 (mm)

Weight of indoor unit (Kg)

:

19 (kg)

OUTDOOR

Size of outdoor unit (mm):967 x 880 x 320 (mm)
Weight of outdoor unit (Kg):77 (kg)

Samsung 1-way Ceiling Cassette 24.000Btu AC024HB4DED /...

24,800,000 VND

TECHNICAL SPECIFICATIONS

Origin

:

Brand: Korea - Country of manufacture: China

Refrigerant type

:

R22

Machine type

:

Non-inverter (no power saving) - 1 way type (cooling only)

Cooling capacity

:

2.5 Hp (2.5 Horse) - 24.000 Btu/h

Use for room

:

Area 31 - 34 m² or 93 - 102 m³ gas (suitable for living room, office)

Power supply (Ph / V / Hz)

:

1 phase, 220 - 240V, 50Hz

Power consumption of electricity

:

2,4 Kw

Gas copper pipe size (mm)

:

6.35 / 15.88

COOLER

Size of indoor unit (mm)

:204 x 840 x 840 (mm)

Weight of indoor unit (Kg)

:15.5 (kg)

OUTDOOR

Size of outdoor unit (mm)

:638 x 880 x 310 (mm)

Weight of outdoor unit (Kg)

:51 (kg)

Samsung 1-way ceiling conditioner 18,000 Btu...

19,500,000 VND

TECHNICAL SPECIFICATIONS

Origin

:

Brand: Korea - Country of manufacture: China

Refrigerant type

:

R22

Machine type

:

Non-inverter (no power saving) - 1 way type (cooling only)

Cooling capacity

:

2.0 Hp (2.0 Horse) - 19.000 Btu/h

Use for room

:

Area 24 - 27 m² or 72 - 81 m³ gas (suitable for living room, office)

Power supply (Ph / V / Hz)

:

1 phase, 220 - 240V, 50Hz

Power consumption of electricity

:

1,8 Kw

Gas copper pipe size (mm)

:

6.35 / 12.7

COOLER

Size of indoor unit (mm)

:

204 x 840 x 840 (mm)

Weight of indoor unit (Kg)

:

15.5 (kg)

OUTDOOR

Size of outdoor unit (mm)

:

638 x 880 x 310 (mm)

Weight of outdoor unit (Kg)

:

42 (kg)

Dry transformer-22/0.4kv 3150kva. Dyn11 (CU-CU)

3,280,000,000 VND

Cast-resin Transformer

 

       Customized solutions for various applications and needs can be supplied up to maximum voltage of 35kV, and maximum power rating of 30MVA. Safe, silent, and semi-permanent cast-resin transformers of Hyosung Heavy Industries, are suitable for places where installation conditions are limited, where fire prevention is required, and where eco-friendliness, and resistance to harsh environment is critical.

        Having developed the cast-resin transformer for the first time in Korea, Hyosung Heavy Industries received certifications from international bodies, including ISO, and CESI, and received certification for fire-retardancy (F1, 2000), Thermal-Accelerated Degradation (IEEE Std C57.12.60-1998 & RS C 0018-2006, 2008), and seismic resistance (IEEE Std 344-1987, Q-Class) for the first time in Korea, proving capabilities for quality and technology leadership.

Dry transformer-22/0.4kv 2500kva. Dyn11 (CU-CU)

2,745,000,000 VND

Cast-resin Transformer

 

       Customized solutions for various applications and needs can be supplied up to maximum voltage of 35kV, and maximum power rating of 30MVA. Safe, silent, and semi-permanent cast-resin transformers of Hyosung Heavy Industries, are suitable for places where installation conditions are limited, where fire prevention is required, and where eco-friendliness, and resistance to harsh environment is critical.

        Having developed the cast-resin transformer for the first time in Korea, Hyosung Heavy Industries received certifications from international bodies, including ISO, and CESI, and received certification for fire-retardancy (F1, 2000), Thermal-Accelerated Degradation (IEEE Std C57.12.60-1998 & RS C 0018-2006, 2008), and seismic resistance (IEEE Std 344-1987, Q-Class) for the first time in Korea, proving capabilities for quality and technology leadership.

 

Dry transformer-22/0.4kv 2250kva. Dyn11 (CU-CU)

2,196,000,000 VND

Cast-resin Transformer

 

       Customized solutions for various applications and needs can be supplied up to maximum voltage of 35kV, and maximum power rating of 30MVA. Safe, silent, and semi-permanent cast-resin transformers of Hyosung Heavy Industries, are suitable for places where installation conditions are limited, where fire prevention is required, and where eco-friendliness, and resistance to harsh environment is critical.

        Having developed the cast-resin transformer for the first time in Korea, Hyosung Heavy Industries received certifications from international bodies, including ISO, and CESI, and received certification for fire-retardancy (F1, 2000), Thermal-Accelerated Degradation (IEEE Std C57.12.60-1998 & RS C 0018-2006, 2008), and seismic resistance (IEEE Std 344-1987, Q-Class) for the first time in Korea, proving capabilities for quality and technology leadership.

 

Dry transformer-22/0.4kv 2000kva. Dyn11 (CU-CU)

1,968,000,000 VND

Cast-resin Transformer

 

       Customized solutions for various applications and needs can be supplied up to maximum voltage of 35kV, and maximum power rating of 30MVA. Safe, silent, and semi-permanent cast-resin transformers of Hyosung Heavy Industries, are suitable for places where installation conditions are limited, where fire prevention is required, and where eco-friendliness, and resistance to harsh environment is critical.

        Having developed the cast-resin transformer for the first time in Korea, Hyosung Heavy Industries received certifications from international bodies, including ISO, and CESI, and received certification for fire-retardancy (F1, 2000), Thermal-Accelerated Degradation (IEEE Std C57.12.60-1998 & RS C 0018-2006, 2008), and seismic resistance (IEEE Std 344-1987, Q-Class) for the first time in Korea, proving capabilities for quality and technology leadership.

 

Dry transformer-22/0.4kv 1600kva. Dyn11 (CU-CU)

1,754,000,000 VND

Cast-resin Transformer

 

       Customized solutions for various applications and needs can be supplied up to maximum voltage of 35kV, and maximum power rating of 30MVA. Safe, silent, and semi-permanent cast-resin transformers of Hyosung Heavy Industries, are suitable for places where installation conditions are limited, where fire prevention is required, and where eco-friendliness, and resistance to harsh environment is critical.

        Having developed the cast-resin transformer for the first time in Korea, Hyosung Heavy Industries received certifications from international bodies, including ISO, and CESI, and received certification for fire-retardancy (F1, 2000), Thermal-Accelerated Degradation (IEEE Std C57.12.60-1998 & RS C 0018-2006, 2008), and seismic resistance (IEEE Std 344-1987, Q-Class) for the first time in Korea, proving capabilities for quality and technology leadership.

Dry transformer-22/0.4kv 1250kva. Dyn11 (CU-CU)

1,470,000,000 VND

Cast-resin Transformer

 

       Customized solutions for various applications and needs can be supplied up to maximum voltage of 35kV, and maximum power rating of 30MVA. Safe, silent, and semi-permanent cast-resin transformers of Hyosung Heavy Industries, are suitable for places where installation conditions are limited, where fire prevention is required, and where eco-friendliness, and resistance to harsh environment is critical.

        Having developed the cast-resin transformer for the first time in Korea, Hyosung Heavy Industries received certifications from international bodies, including ISO, and CESI, and received certification for fire-retardancy (F1, 2000), Thermal-Accelerated Degradation (IEEE Std C57.12.60-1998 & RS C 0018-2006, 2008), and seismic resistance (IEEE Std 344-1987, Q-Class) for the first time in Korea, proving capabilities for quality and technology leadership.