Korean polymer lightning protector PLA.

8,250,000 VND

 

Working principle of lightning protection valve:

When there is an atmospheric overvoltage or internal overvoltage problem. The lightning protection valve generates a path that returns current to earth and then restores the normal state under operating conditions. Some current line surge arrester and medium voltage lightning arrester have a breaker connected in series to the end of the surge valve. This breaker will operate when there is a power frequency failure

If you need advice or installation, contact: 0969002382 for the best support.

LIGHTNING CONDUCTOR (LA)

7,500,000 VND

LIGHTNING CONDUCTOR (LA)

Applicable standards: IEC 60099-4

Type: Gapless, consisting of metal oxide resistor discs stacked and linked to 2 electrodes.

Lightning protection level: Level 1

Rated voltage (Ur): 12kV to 48kV

Rated discharge current: 10kA

Rated frequency: 50Hz

Creepage distances: 440mm to 1477mm

Insulation: Polymer (Silicone Rubber)

cut fuse with load LBFCO) - POLYMER

12,500,000 VND

cut fuse with load LBFCO) - POLYMER

Applicable standards: ANSI C37.42, IEC 60282-2, IEC 61109

Rated voltage: 24kV

Rated current: 100A & 200A

Rated frequency: 50Hz

Short-circuit breaking capacity: 12kA

Impulse voltage endurance (BIL): 150kV

Leakage current length: 635mm

Insulation: Polymer (Silicone Rubber)

cuter fuse with load(LBFCO)

11,500,000 VND

cuter fuse with load(LBFCO)

Applicable standards: ANSI C37.42, IEC 60282-2, IEC 62217, IEC 61109

Rated voltage: 24kV

Rated current: 100A & 200A

Rated frequency: 50Hz

Short-circuit breaking capacity: 12kA

Impulse voltage endurance (BIL): 125kV, 150kV

Leakage current length: 340mm, 440mm

Insulation material: Porcelain

fuse itself falls (FCO) - POLYMER

8,500,000 VND

 fuse itself falls (FCO) - POLYMER

Applicable standards: ANSI C37.42, IEC 60282-2, IEC 62217, IEC 61109

Rated voltage: 24kV & 35kV

Rated current: 100A & 200A

Rated frequency: 50Hz

Short-circuit breaking capacity: 12kA

Impulse voltage endurance (BIL):

+ Type 24kV: 150kV

+ Type 35kV: 200kV

Leakage current length:

+ Type 24kV: 635mm

+ Type 35kV: 980mm

Insulation: Polymer (Silicone Rubber)

fuse itself falls (FCO)

6,850,000 VND

fuse itself falls (FCO)I (FCO)

Applicable standards: ANSI C37.42, IEC 60282-2, IEC 62217, IEC 61109

Rated voltage: 24kV & 35kV

Rated current: 100A & 200A

Rated frequency: 50Hz Short-circuit

breaking capacity: 12kA

Impulse voltage endurance (BIL):

+ Type 24kV: 125kV; 150kV

+ Type 35kV: 170kV

Leakage current length:

+ Type 24kV: 340mm, 440mm

+ Type 35kV: 720mm

Insulation material: Porcelain